WECO 635-700 XS2

technical details:

  • nominal thermal load = kW 760 - 960
  • nominal air flow = m3/h 74.000
  • compression = max. Pa 780
  • total pressure increase = Pa 720
  • shaft power = kW 16
  • exhaust gas loss = min. % 4,00
  • electrical connection = V/Hz 400/3N~/50
  • power consumption (max. device) = kW 17
  • rated current (max. hole. device) = A 25
  • power consumption = kW 16
  • rated current = A 32
  • hedge = A 3×32
  • temperature increase = KW 72
  • Sound pressure level = LpA 1m2) dB (A) 73
  • air outlet opening Ø = mm 6×480
  • exhaust gas stub Ø = mm 30×30
  • length = mm 5440
  • wide = mm 2250
  • high = mm 2540
  • weight (with forced-air oil burner) = kg 2450